📍 28195 KEHRIG ST, CHESTERFIELD, MI 48047🏭 Metal Crown, Closure, and Other Metal Stamping (except Automotive) (NAICS 332119)📅 2018-10-15
$11,000.00
Total Penalties
50
Citations
27/100
Risk Score
414
Analysis Words
Enforcement Analysis
According to U.S. Department of Labor enforcement records, INNOVATIVE TOOL INC — a metal crown, closure, and other metal stamping (except automotive) facility located at 28195 KEHRIG ST, CHESTERFIELD, MI 48047 — was the subject of a formal OSHA inspection that resulted in 50 citation(s) and cumulative proposed penalties of $11,000.00. The inspection case was opened on 2018-10-15.
The volume of citations issued during this inspection suggests systematic compliance deficiencies rather than isolated incidents. Facilities with 10 or more citations typically face comprehensive abatement requirements and may be subject to follow-up inspections.
BLS Injury Data: According to the Bureau of Labor Statistics (2022), this industry sector has an occupational injury rate of 3.3 per 100 full-time workers — 22% above the national average of 2.7. The sector fatality rate is 2.3 per 100,000 workers.
EPA Environmental Record: The EPA shows no current violations for this facility. regulated under: Clean Water Act. Source: EPA ECHO database.
Industry Benchmark: The total penalty of $11,000.00 is 71% above the national average of $6,436.62 for facilities in the Manufacturing sector (NAICS 332119). This sector encompasses 82,943 inspected facilities nationwide with aggregate penalties totaling $533.9M.
State Context: Within MI, this facility's penalty places it at the 98th percentile among 106,495 inspected facilities. The statewide average penalty is $1,470.95.
Citation Analysis: The inspection produced 50 citations spanning 9 distinct OSHA regulatory standards. The citation breakdown includes: 10 other-than-serious — The violation has a direct relationship to job safety and health but is unlikely to cause death or serious physical harm.5 serious — A workplace hazard that could cause death or serious physical harm exists, and the employer knew or should have known about the condition.
Enforcement Timeline: Citations were issued beginning September 18, 2014 with the latest abatement deadline set for October 21, 2014. Of the 50 total citations, 15 (30%) have been marked as abated in DOL records, which may indicate ongoing compliance gaps requiring further regulatory attention.
Penalty Assessment: The cumulative penalty of $11,000.00 reflects OSHA's gravity-based penalty calculation methodology, which considers the severity of potential injury, the probability of occurrence, the employer's size, good faith, and violation history. The per-citation average of $220.00 falls within the standard penalty range.
Citation Matrix — 50 Citations
29 CFR 4081.2131(01)
Other-than-Serious
Penalty: $0.00Gravity: nanIssued: September 18, 2014Abated: ✓ Yes
29 CFR 4081.2169
Other-than-Serious
Penalty: $0.00Gravity: nanIssued: September 18, 2014Abated: ✓ Yes
29 CFR 4081.2622(02)
Other-than-Serious
Penalty: $0.00Gravity: nanIssued: September 18, 2014Abated: ✓ Yes
29 CFR 1910.305(b)(01)
Electrical — Wiring Methods & Components
Other-than-Serious
Penalty: $0.00Gravity: nanIssued: September 18, 2014Abated: ✓ Yes
29 CFR 1910.305(b)(02)
Electrical — Wiring Methods & Components
Other-than-Serious
Penalty: $0.00Gravity: nanIssued: September 18, 2014Abated: ✓ Yes
29 CFR 1910.305(g)(01)
Electrical — Wiring Methods & Components
Other-than-Serious
Penalty: $0.00Gravity: nanIssued: September 18, 2014Abated: ✓ Yes
29 CFR 4081.4007(07)
Other-than-Serious
Penalty: $0.00Gravity: nanIssued: September 18, 2014Abated: ✓ Yes
29 CFR 4081.4965(01)
Other-than-Serious
Penalty: $0.00Gravity: nanIssued: September 18, 2014Abated: ✓ Yes
29 CFR 4081.5815(02)
Other-than-Serious
Penalty: $0.00Gravity: nanIssued: September 18, 2014Abated: ✓ Yes
29 CFR 4081.5815(09)
Other-than-Serious
Penalty: $0.00Gravity: nanIssued: September 18, 2014Abated: ✓ Yes
29 CFR 1910.303(g)(02)
Electrical — General Requirements
Serious
Penalty: $225.00Gravity: nanIssued: September 18, 2014Abated: ✓ Yes
29 CFR 1910.147(c)(04)
Control of Hazardous Energy (Lockout/Tagout)
Serious
Penalty: $750.00Gravity: nanIssued: September 18, 2014Abated: ✓ Yes
29 CFR 1910.147(c)(05)
Control of Hazardous Energy (Lockout/Tagout)
Serious
Penalty: $0.00Gravity: nanIssued: September 18, 2014Abated: ✓ Yes
29 CFR 1910.147(c)(07)
Control of Hazardous Energy (Lockout/Tagout)
Serious
Penalty: $0.00Gravity: nanIssued: September 18, 2014Abated: ✓ Yes
29 CFR 1910.147(c)(07)
Control of Hazardous Energy (Lockout/Tagout)
Serious
Penalty: $0.00Gravity: nanIssued: September 18, 2014Abated: ✓ Yes
This report is compiled from publicly available U.S. Department of Labor enforcement data under the Freedom of Information Act. SVEP Navigator is an independent research and analysis platform and is not affiliated with, endorsed by, or connected to OSHA, the Department of Labor, or any federal agency. Information is provided for research, educational, and compliance planning purposes only and does not constitute legal advice. Penalty amounts shown are proposed penalties and may have been modified through contest proceedings or settlement.