📍 MILL STREET, FREEPORT, PA 16229🏭 Industry Sector 00 (NAICS 000000)📅 1998-03-28
$116,580.00
Total Penalties
67
Citations
48/100
Risk Score
373
Analysis Words
Enforcement Analysis
According to U.S. Department of Labor enforcement records, FREEPORT BRICK COMPANY — a industry sector 00 facility located at MILL STREET, FREEPORT, PA 16229 — was the subject of a formal OSHA inspection that resulted in 67 citation(s) and cumulative proposed penalties of $116,580.00. The inspection case was opened on 1998-03-28.
Cumulative penalties significantly exceed the national median for OSHA enforcement actions. The penalty amount suggests multiple high-gravity citations, indicating conditions that presented a substantial probability of death or serious physical harm to employees.
Industry Benchmark: The total penalty of $116,580.00 is more than 97.5× the national average of $1,195.75 for facilities in the Other sector (NAICS 000000). This sector encompasses 1,316,687 inspected facilities nationwide with aggregate penalties totaling $1,574.4M.
State Context: Within PA, this facility's penalty places it at the 100th percentile among 84,409 inspected facilities. The statewide average penalty is $3,015.83.
Citation Analysis: The inspection produced 67 citations spanning 9 distinct OSHA regulatory standards. The citation breakdown includes: 13 serious — A workplace hazard that could cause death or serious physical harm exists, and the employer knew or should have known about the condition.2 other-than-serious — The violation has a direct relationship to job safety and health but is unlikely to cause death or serious physical harm.
Enforcement Timeline: Citations were issued beginning June 1, 1998 with the latest abatement deadline set for April 9, 2001. Of the 67 total citations, 15 (22%) have been marked as abated in DOL records, which may indicate ongoing compliance gaps requiring further regulatory attention.
Penalty Assessment: The cumulative penalty of $116,580.00 reflects OSHA's gravity-based penalty calculation methodology, which considers the severity of potential injury, the probability of occurrence, the employer's size, good faith, and violation history. The per-citation average of $1,740.00 falls within the standard penalty range.
The inspection of Freeport Brick Company revealed a profound systemic breakdown in safety management, evidenced by the staggering volume of
Citation Matrix — 67 Citations
29 CFR 1910.134(b)(02)
Fall Protection — General Requirements
Serious
Penalty: $1,080.00Gravity: 03Issued: June 29, 1998Abated: ✓ Yes
29 CFR 1910.1000(c)
Serious
Penalty: $0.00Gravity: 10Issued: June 29, 1998Abated: ✓ Yes
29 CFR 1910.1000(e)
Serious
Penalty: $0.00Gravity: 10Issued: June 29, 1998Abated: ✓ Yes
29 CFR 1910.22(a)(01)
Walking-Working Surfaces — General
Other-than-Serious
Penalty: $0.00Gravity: 01Issued: June 1, 1998Abated: ✓ Yes
29 CFR 1910.134(b)(03)
Fall Protection — General Requirements
Other-than-Serious
Penalty: $0.00Gravity: 01Issued: June 1, 1998Abated: ✓ Yes
29 CFR 1910.23(c)(03)
Guarding Floor & Wall Openings
Serious
Penalty: $1,750.00Gravity: 10Issued: June 1, 1998Abated: ✓ Yes
29 CFR 1910.1200(h)
Hazard Communication Standard (Chemical Safety)
Serious
Penalty: $1,750.00Gravity: 10Issued: June 1, 1998Abated: ✓ Yes
29 CFR 1910.1200(h)(01)
Hazard Communication Standard (Chemical Safety)
Serious
Penalty: $0.00Gravity: 01Issued: June 1, 1998Abated: ✓ Yes
29 CFR 1910.215(d)(01)
Abrasive Wheel Machinery
Serious
Penalty: $0.00Gravity: 01Issued: March 22, 2001Abated: ✓ Yes
29 CFR 1910.219(b)(01)
Mechanical Power Transmission
Serious
Penalty: $840.00Gravity: 02Issued: March 22, 2001Abated: ✓ Yes
29 CFR 1910.219(d)(01)
Mechanical Power Transmission
Serious
Penalty: $840.00Gravity: 02Issued: March 22, 2001Abated: ✓ Yes
29 CFR 1910.219(e)(01)
Mechanical Power Transmission
Serious
Penalty: $0.00Gravity: 02Issued: March 22, 2001Abated: ✓ Yes
29 CFR 1910.303(g)(02)
Electrical — General Requirements
Serious
Penalty: $2,100.00Gravity: 10Issued: March 22, 2001Abated: ✓ Yes
29 CFR 1910.304(d)(01)
Electrical — Wiring Design & Protection
Serious
Penalty: $2,100.00Gravity: 10Issued: March 22, 2001Abated: ✓ Yes
29 CFR 1910.304(f)(04)
Electrical — Wiring Design & Protection
Serious
Penalty: $1,050.00Gravity: 03Issued: March 22, 2001Abated: ✓ Yes
This report is compiled from publicly available U.S. Department of Labor enforcement data under the Freedom of Information Act. SVEP Navigator is an independent research and analysis platform and is not affiliated with, endorsed by, or connected to OSHA, the Department of Labor, or any federal agency. Information is provided for research, educational, and compliance planning purposes only and does not constitute legal advice. Penalty amounts shown are proposed penalties and may have been modified through contest proceedings or settlement.